Hardware Installation

Installation of SCSI equipment requires a 50-pin SCSI ribbon cable at least 30 inches long. The cable must pass through the slot in the case support that is near the front of the computer system. The cable must NOT under any circumstances pass over the center case support.

A cable that fits perfectly would be:


SCSI ID's are determined by the setting of three jumpers that represent the binary representation of the SCSI ID. Use the following table to compute SCSI ID:

SCSI ID Jumper
SCSI ID210
0
1 X
2 X
3 XX
4X
5X X
6XX
7XXX


Conner 4207S Jumper Settings (Drive Bay 3) (Middle bottom of drive) should be:

Conner 4207S Jumper Settings
JumperDescriptionSetting
E1SCSI ID 0Off
E2SCSI ID 1Off
E3SCSI ID 2Off
E4RESERVEDOff
E5Disable SpinOff
E6Delay SpinOff
E7Disable ParityOff

Termination must be enabled (red bars at rear of drive). Drive must be installed last in the SCSI Chain.


Sony SDT-5000 DDS-2 Dat Drive Jumper settings: (Drive Bay 2)

Sony SDT-5000 Jumper Settings
JumperDescriptionSetting
J1SCSI ID 2On
J2SCSI ID 1On
J3SCSI ID 0Off
J4DATA COMPRESSION DISABLEOff
J5SCSI PARITYOn
J6RESERVEDOff
J7TERMINATOR ONOff
J8TERMINATOR POWEROff

The DAT Drive must be installed in middle of the SCSI Chain.

Note: When installing the DAT Faceplate, the faceplate door must be held open while inserting it into the DAT mechanism.


SMC Elite Ultra 16C Ethernet Card (ISA Slot 4)

Hardset to:

I/O        0x300
IRQ        10
RAM        0xcc00
ROM        NONE


Buslogic 946C Revision E (PCI Slot 1)

Jumper JP4 and JP5 all off

Software Settings:

(These are chosen when selecting Automatic Configuration)

Configuration Menu settings:

Summary of Configuration
DescriptionSetting
Adapter IO Port1000h
Adapter TypeBT-946C
BIOS AddressC8000h
Interrupt Channel11
DMA Channel Emulation5
DMA Transfer RateN/A
Adapter SCSI ID7
SCSI ParityOn
Adapter SCSI TerminationOn
DOS Space > 1GBNo
Firmware Revision4.25J
BIOS Revision4.92E

Configure Adapter
Host Adapter Interrupt Channel11
ISA DMA Channel Emulation5
DMA Transfer RateN/A
Host Adapter SCSI ID7
SCSI ParityOn
Host Adapter SCSI TerminationOn
Host Adapter Interrupt Trigger Type Level
Host Adapter Interrupt PINA

Configure Device
Enable Fast TransferAll Yes
Enable Sync NegotiationAll Yes
Enable DisconnectionAll Yes

Advanced Options
Adapter BIOSDisable
Adapter BIOS Controls BootingYes
Adapter BIOS Supports > 1 GBNo
BIOS Supports Removable disks as Fixed DisksNo
BIOS Support for > 2 DrivesYes
Interrupt Generated for BIOS CommandsNo
BIOS Floptical DrivesNO
SCSI Bus ResetEnable
Reserved RAM for Bios Access200
Set ISA Compatible IO PortPrimary